Home
Up

 

 

Gear Position Sensor

Resistances and voltages (between pink and black wires)
1st = 560 Ohms 1.8V
2nd = 830 Ohms 2.26V
3rd = 1.5k Ohms 2.99V
4th = 2.7k Ohms 3.68V
5th = 6.8k Ohms 4.38V
6th = 15k Ohms 4.70V
Neutral = open on pink wire 5.08V, connected through the blue wire for neutral light

Sensor wire colours.
TPS - Y
IAP - G/B
AAP - G/Y
ECT - B/Bl
IAT - DG
all have B/Br as common earth
CKP - W + G
CPS - B/Y + Br

Fuel Lines
Return line, to replace with braided Stainless Steel line you will need 270mm of 8mm I/D hose
2000 return line is preformed with the desired bends for the tank and pump nipples. 2000 return line part number 15801-24F10

Main Feed line, depending on how you want to route the line, depends on what you need. The stock line has the correct bends preformed.

Fuel Pump

2000 pump numbers CB8-B7-OB15

1999 pump numbers CB8-B7-NA28

paper filter changes between 1999 and 2000 model...inlet and outlets are different

Regulator

Regulator is a rising rate variety, taking its baseline from the Inlet manifold. It holds pressure at 3 bar (43psi) above Intake pressure

a good replacement is the FSE Power Boost Valve PBV384372 (FSE phone number 01784 493555)

An adjustable rising rate regulator suitable for remote instalations. I shall be getting one soon to try with an aftermarket fuel pump. I will keep you informed of my progress

 

 

 

© 200mph.org.uk